Sunday, December 24, 2017

20151019 Blood Conservation and Triggers - YouTube
src: i.ytimg.com

Intraoperative blood salvage, also known as autologous blood transfusion or cell salvage, is a medical procedure involving recovering blood lost during surgery and re-infusing it into the patient. It is a major form of autotransfusion.

It has been used for many years and gained greater attention over time as risks associated with allogenic (separate-donor) blood transfusion have seen greater publicity and more fully appreciated. Several medical devices have been developed to assist in salvaging the patient's own blood in the perioperative setting. These are used frequently in cardiothoracic and vascular surgery, in which blood usage has traditionally been high. With a greater effort to avoid adverse events due to transfusion there has also been an emphasis on blood conservation (see bloodless surgery).


Video Intraoperative blood salvage



Background

Providing safe blood for transfusion remains a challenge despite advances in preventing transmission of hepatitis B, hepatitis C, AIDS/HIV, West Nile virus (WNV), and transfusion-transmitted bacterial infection. Human errors such as misidentifying patients and drawing blood samples from the wrong person present much more of a risk than transmissible diseases.

Additional risks include transfusion related acute lung injury (TRALI), a potentially life-threatening condition with symptoms such as dyspnea, fever, and hypotension occurring within hours of transfusion, and also transfusion-associated immunomodulation, which may suppress the immune response and cause adverse effects such as a small increase in the risk of postoperative infection.

Other risks such as variant Creutzfeldt-Jakob disease (vCJD), an invariably fatal disease, remain worrisome. Blood centers worldwide have instituted criteria to reject donors who may have been exposed to vCJD. Screening for transmissible diseases and deferral policies for vCJD designed to improve safety have contributed to shrinking the donor pool. Blood shortages exist in the United States and worldwide. In many industrialized countries 5% or less of the eligible population are blood donors.

As a result, the global medical community has increasingly moved from allogenic blood (blood collected from another person) towards autologous infusion, in which patients receive their own blood. Another impetus for autologous transfusion is the position of Jehovah's Witnesses on blood transfusions. For religious reasons, Jehovah's Witnesses will not accept any allogeneic transfusions from a volunteer's blood donation, but may accept the use of autologous blood salvaged during surgery to restore their blood volume and homeostasis during the course of an operation, although not autologous blood donated beforehand. There are other religious/ non-religious individuals besides Jehovah's Witnesses that accept Intraoperative blood salvage due to personal choice.


Maps Intraoperative blood salvage



Bloodless options

Ways to avoid the adverse events associated with allogenic transfusion are often grouped under the umbrella phrase bloodless surgery. There are several so-called bloodless options. These include:

  • Minimally invasive surgical techniques
  • Erythropoietin (a hormone that stimulates peripheral stem cells in the bone marrow to produce red blood cells)
  • Blood substitutes such as blood volume expanders and oxygen carriers (the latter as yet unlicensed in North America)

Quick biochemical markers for assessment of quality control of ...
src: media.springernature.com


Blood salvage procedures

Several processes have been developed to assist in salvaging the patient's own whole blood in the perioperative setting. These can be categorized into three general types of salvage procedures:

  1. Cell processors and salvage devices that wash and save red blood cells, i.e. "cell washers" or RBC-savers
  2. Direct transfusion
  3. Ultrafiltration of whole blood

Regardless of manufacturer, there are many types of cell processors. Cell processors are red cell washing devices that collect anticoagulated shed or recovered blood, wash and separate the red blood cells (RBC) by centrifugation, and reinfuse the RBC. RBC washing devices can help remove byproducts in salvaged blood such as activated cytokines, anaphylatoxins, and other waste substances that may have been collected in the reservoir suctioned from the surgical field. However, they also remove viable platelets, clotting factors, and other plasma proteins essential to whole blood and homeostasis. The various RBC-savers also yield RBC concentrates with different characteristics and quality.

Direct transfusion is a blood salvaging method associated with cardiopulmonary bypass (CPB) circuits or other extracorporeal circuits (ECC) that are used in surgery such as coronary artery bypass grafts (CABG), valve replacement, or surgical repair of the great vessels. Following bypass surgery the ECC circuit contains a significant volume of diluted whole blood that can be harvested in transfer bags and re-infused into patients. Residual CPB blood is fairly dilute ([Hb] = 6-9 g/dL; 60-90 g/L) compared to normal values (12-18 g/dL; 120-180 g/L) and can also contain potentially harmful contaminants such as activated cytokines, anaphylatoxins, and other waste substances that have been linked to organ edema and organ dysfunction and need a diuretic to reverse.

Hemofiltration or ultrafiltration devices constitute the third major type of blood salvage in operating rooms. In general, ultrafiltration devices filter the patient's anticoagulated whole blood. The filter process removes unwanted excess non-cellular plasma water, low molecular weight solutes, platelet inhibitors and some particulate matter through hemoconcentration, including activated cytokines, anaphylatoxins, and other waste substances making concentrated whole blood available for reinfusion. Hemofilter devices return the patient's whole blood with all the blood elements and fractions including platelets, clotting factors, and plasma proteins with a substantial Hb level. Presently, the only whole blood ultrafiltration device in clinical use is the Hemobag. These devices do not totally remove potentially harmful contaminants that can be washed away by most RBC-savers. However, the contaminants that are potentially reduced by using RBC-savers, as shown by data from in vitro laboratory tests, are transient and reversible in vivo with hemostatic profiles returning to baselines within hours. The key is that coagulation and homeostasis are immediately improved with the return of concentrated autologous whole blood.

Over the years numerous studies have been done to compare these methods of blood salvage in terms of safety, patient outcomes, and cost effectiveness, often with equivocal or contradictory results.


Patient blood management (Intraoperative bleeding management) By ...
src: images.slideplayer.com


See also

  • Autotransfusionist
  • Bloodless surgery

Quick biochemical markers for assessment of quality control of ...
src: media.springernature.com


References


Mechanical methods of reducing blood transfusion in cardiac ...
src: www.bmj.com


Further reading

  • Beckmann SR, Carlile D, Bissinger RC, Burrell M, Winkler T, Shely WW (June 2007). "Improved coagulation and blood conservation in the golden hours after cardiopulmonary bypass". The Journal of Extra-corporeal Technology. 39 (2): 103-8. PMID 17672193. 
  • Beckmann S, Lynn P, Miller S, Harris R, DiMarco RF, Ross JE (May 2013). "Evaluation of coagulation factors and platelet function from an off-line modified ultrafiltration technique for post-cardiopulmonary bypass circuit blood recovery". Perfusion. 28 (3): 214-22. doi:10.1177/0267659112470710. PMID 23271047. 
  • Colli A, Balduzzi S, Ruyra X (2012). "The Hemobag: the modern ultrafiltration system for patients undergoing cardiopulmonary by pass". Journal of Cardiothoracic Surgery. 7: 55. doi:10.1186/1749-8090-7-55. PMC 3410786 . PMID 22697396. 
  • Delaney E, Rosinski D, Ellis H, Samolyk KA, Riley JB (June 2010). "An in-vitro comparison between Hemobag and non-Hemobag ultrafiltration methods of salvaging circuit blood following cardiopulmonary bypass". The Journal of Extra-corporeal Technology. 42 (2): 128-33. PMC 4680036 . PMID 20648897. 
  • Harm SK, Waters JH, Lynn P, et al. (March 2012). "Changes in mechanical fragility and free hemoglobin levels after processing salvaged cardiopulmonary bypass circuit blood with a modified ultrafiltration device". The Journal of Extra-corporeal Technology. 44 (1): 21-5. PMC 4557435 . PMID 22730860. 
  • McNair E, McKay W, Qureshi AM, et al. (December 2013). "Outcomes and biochemical parameters following cardiac surgery: effects of transfusion of residual blood using centrifugation and multiple-pass hemoconcentration". Journal of Cardiothoracic and Vascular Anesthesia. 27 (6): 1174-80. doi:10.1053/j.jvca.2013.03.011. PMID 23988781. 
  • Moskowitz DM, Klein JJ, Shander A, et al. (September 2006). "Use of the Hemobag for modified ultrafiltration in a Jehovah's Witness patient undergoing cardiac surgery". The Journal of Extra-corporeal Technology. 38 (3): 265-70. PMC 4680820 . PMID 17089515. 
  • Samolyk KA, Beckmann SR, Bissinger RC (October 2005). "A new practical technique to reduce allogeneic blood exposure and hospital costs while preserving clotting factors after cardiopulmonary bypass: the Hemobag". Perfusion. 20 (6): 343-9. doi:10.1191/0267659105pf831oa. PMID 16363320. 

Patient blood management (Intraoperative bleeding management) By ...
src: images.slideplayer.com


External links

  • UK: Serious Hazards of Transfusion Reports (PDF)
  • Transfusion-associated adverse events
  • Anemia Institute
  • NATA, the Network for Advancement of Transfusion Alternatives
  • NoBlood
  • Physicians and Nurses for Blood Conservation
  • SABM, the Society for the Advancement of Blood Management

Source of article : Wikipedia